10-7-10-snyatie-sistemy-ehlektronnojj-sistemojj-upravleniya-mikroklimatom-ehum.html
10.7.10. Removal of system electronic control system of a microclimate (EUM)If the switch of system does not work, then it is necessary to replace all control panel.
The sequence of actions at removal of system an electronic control system of a microclimate (EUM):
1) remove the forward panel, having accurately hooked its edge a penknife and having delayed outside.
|
Fig. 10.79. Removal of the forward panel
|
Handles of management will remain on the place (fig. 10.79);
2) turn off fixing bolts (4 torx);
3) remove the console basis (accurately press the screw-driver edge);
NOTE
For removal of the basis of the console at first push the radio tape recorder forward on several centimeters.
|
|
Fig. 10.80. The screw in the console basis
|
4) unscrew the screw behind the basis of the console (fig. 10.80) and push forward the console a little;
5) disconnect sockets from switches and the radio receiver and remove the console.
6) incline the control panel (block) down and disconnect the socket and a hose;
7) remove the block.
Assembly is made as it should be, the return to dismantling.
|